Technical specifications for IMEON 9.12
GRID AC (ON-GRID & OFF-GRID)
-
Rated output power
9000 W
-
Maximum output power (3 sec)
12000 W
-
AC voltage / Frequency (input & output)
3/N/PE; 230/400 Vac (±15 %) / 50 Hz, 60 Hz (±5 Hz)
-
Nominal output current
13 A / phase
-
Maximum input current
17,5 A / phase
-
Feed in to grid
Programmable (yes by default)
-
Energy consumption priorities
Programmable (PV / Storage / Grid)
SOLAR INSTALLATION
-
Maximum input power
Up to 12 000 Wp (1)
-
Number of MPPT inputs
2
-
MPPT voltage range
380 V – 750 V
-
Maximum input current
2 x 18 A
-
Maximum input voltage
850 V
-
Maximum efficiency
DC to AC : >95,5% (94,5% EU)
BATTERY & CHARGE
-
DC nominal voltage
48 Vdc
-
DC range voltage
42 – 62 Vdc
-
Maximum discharge current
200 A
-
Maximum charging current
160 A
-
Type of batteries
Lead-acid, Lithium(2)
-
Charging curve
3-phase (Bulk / Absorption / Float)
-
Maximum efficiency
PV -> batterie : >94% / Batterie <–> AC : >93%
-
Battery charge
Programmable (threshold / timing: multiple range by AC Grid)
-
Battery discharge
Programmable ( 2 thresholds according to grid availability)
GENERAL
-
Dimensions (w x h x d)
580 x 800 x 240 mm / 22.85 x 31.5 x 9.45 inch
-
Protection category
IP 20 (indoor installation)
-
Weight
46 kg
-
Technology
TL (transformless)
-
Operating mode
Smart grid / Back up – UPS / Off grid / On grid / VPP Ready
-
OS / Processor
OS: Linux Debian – CPU: ARM Cortex (Texas Instrument) 32 bits
RAM : 8 GO of storage – Artificial Intelligence Inside – IOT Ready -
I / O Connectors
Wifi 802.11 b/g/n 2.4 GHz – 2 USB 2 – 1 Ethernet IP – OTA(4) technology
1 CAN bus – 2 RS485 – 1 relay 230V 16A
4 analog inputs: 1 temperature sensor – 3 current measurements -
Conditions of use
Humidity level: 0 to 90% without condensation
T°C : -20 to + 50°C, degressive power >40°C (15W/°C) -
Compliance
EN 62109-2 / EN 62109-1 / EN 62040-1 / DIN V VDE V 0126-1-1 (+VFR2019) / VDE-AR-N 4105 / EN 50438 DIN VDE V 0124-100 / Synergrid C10/11 / TF3.2.1 / AS4777.2 / AS4777.3 / CEI- 0 21 / RD 1699
-
Guarantee
10 years (3) / Extension to 20 years (optional)